The Principle of Liquid Ring Vacuum Pumps:
The liquid ring vacuum pumps are used the liquid as the pistoned, during the impeller be rotated, those liquid will be throwed exteriorly and formed a movable liquid ring, that interior is hollowed, Since, the impeller is rotated centrifugally to against the pump housing, when the impeller is rotating, the liquid will be leaved from the liquid ring gradually at |
|
inlet,
meanwhile, the space that between two impellers will be enlarged gradually
and sucked air, otherly, when the impeller be rotated to discharge outlet and
the liquid will be into the liquid ring as well as, the space that between
two impellers will be decreased, thus, the compressed air will be discharged
from outlet, so that the repeat cycle will be over again and again. |
Features of Liquid Ring Vacuum Pumps:
l The pumps be applied the principle of liquid ring pistoned, that is specially suitable for being with water, steam & condensable gas etc., suctioned. |
l Compressed at low temp and hi-safety against to easy combustible gas. |
l No metallic surface contacted interiorly, so that, no need any lubricant, low maintenance cost, no oil smoke absolutely. |
l The muffler be installed at outlet, free trouble of noise in operating. |
l Air boosting pumps be installed at inlet, the ultimate pressure cam be reached 6~2 Torr and the vacuum pressure will be advanced & boosted discharging cap. etc., for which being series connected with mechanical booster pumps. |
Applications:
¿ Vacuum Forming ¿ Vacuum Casting ¿ Vacuum System of Medical
¿ Vacuum Drying ¿ Vacuum Conveying ¿ Carburator Testing
¿ Vacuum Lilting ¿ Vacuum Condensing ¿ Fiber Industry
¿ Vacuum Distilling ¿ Vacuum Filling ¿ Polylon & Papermill
¿Vacuum Impreganation ¿ Vacuum Condensing ¿ Chemical Industry etc.
¿ Vacuum Deaerating ¿Vacuum Absorbing Conveyance
SPECIFICATIONS (Two Stage):
* The ultimate vacuum of SWV Type reaches as high as 25 Torr and the
ideal operating pressure below 150 Torr.
The performance of the SWV Type Vacuum Pump is indicated on the basis as follow:
u Suction Air Temperature:20℃
u Discharge Pressure:1atm
u Sealing Liquid Temperature:15℃
Model |
Power (Hp) |
Speed (rpm) |
Pumping Speed (m3/min) |
Bore (in) |
Water Supply (L/min) |
|||
-720mmHg (40Torr) |
-695mmHg (65Torr) |
-670mmHg (90Torr) |
-650mmHg (110Torr) |
|||||
DWV-2 |
2 |
2800 |
0.3 |
0.36 |
0.39 |
0.41 |
1 |
7 |
2 |
3400 |
0.39 |
0.47 |
0.5 |
0.52 |
|||
DWV-3 |
2 |
2800 |
0.55 |
0.7 |
0.73 |
0.72 |
1 |
8 |
3 |
3400 |
0.62 |
0.75 |
0.77 |
0.77 |
|||
SWV-5 |
5 |
1750 |
1.35 |
1.71 |
1.75 |
1.75 |
2 |
18 |
SWV-5D |
3 |
1450 |
0.8 |
1.1 |
1.2 |
1.3 |
2 |
18 |
5 |
1750 |
1.45 |
1.92 |
1.95 |
1.96 |
|||
SWV-7 |
71/2 |
1750 |
2.0 |
2.45 |
2.73 |
2.75 |
2 |
20 |
SWV-7D |
5 |
1450 |
1.3 |
2.3 |
2.5 |
2.53 |
2 |
20 |
71/2 |
1750 |
2.2 |
2.9 |
3.2 |
3.3 |
|||
SWV-10 |
10 |
1750 |
2.3 |
2.92 |
3.35 |
3.35 |
2 |
25 |
SWV-10D |
71/2 |
1450 |
2.8 |
3.2 |
3.3 |
3.3 |
2 |
25 |
10 |
1750 |
3.2 |
3.9 |
4.3 |
4.3 |
|||
SWV-15 |
10 |
1450 |
4.4 |
4.7 |
4.9 |
5.1 |
2 |
40 |
15 |
1750 |
4.5 |
5.5 |
5.61 |
5.83 |
|||
SWV-20 |
15 |
1450 |
4.8 |
5.8 |
6.6 |
6.8 |
2 |
40 |
20 |
1750 |
5.61 |
6.73 |
7.4 |
7.5 |
|||
SWV-25 |
20 |
1450 |
6.0 |
7.1 |
7.6 |
7.9 |
2 |
50 |
25 |
1750 |
7.0 |
8.2 |
9.1 |
9.3 |
|||
SWV-600 |
25 |
1450 |
6.8 |
8.2 |
8.8 |
9 |
3 |
35 |
30 |
1750 |
7.5 |
9.5 |
10 |
10.3 |
|||
SWV-700 |
30 |
1450 |
8 |
9.3 |
10.5 |
10.8 |
3 |
35 |
40 |
1750 |
9.3 |
11.9 |
12.7 |
12.8 |
|||
SWV-900 |
40 |
960 |
13.5 |
15 |
15.3 |
15.4 |
4 |
80 |
50 |
1150 |
15 |
18.5 |
18.4 |
18.4 |
|||
SWV-1300 |
50 |
960 |
18.5 |
20 |
21 |
21.5 |
4 |
85 |
60 |
1100 |
19 |
22 |
23 |
24 |
|||
75 |
1150 |
20 |
24 |
26 |
27 |
|||
SWV-1600 |
60 |
960 |
19 |
23 |
27 |
28 |
4 |
90 |
75 |
1100 |
21 |
25 |
29 |
30 |
|||
100 |
1150 |
23.3 |
27.3 |
32 |
33 |
|||
Standard Coupling transmission type: * Coupling * Base Belt drive type: * Pulley, belt * Base * Pulley cover Option *Three-phase motor *Water-sealed special check valve *Circulating bucket *Atmosphere booster *Muffler bucket *Vacuum gauge * Pressure relief valve * Heat exchanger |
SPECIFICATIONS (Single Stage):
* The ultimate vacuum of SW Type reaches as high as 60 Torr and the ideal operating pressure over than 150 Torr.
The performance of the SW Type Vacuum Pump is indicated on the basis as follow ):
u Suction Air Temperature:20℃
u Discharge Pressure:1atm
u Sealing Liquid Temperature:15℃
Model |
Power (Hp) |
Speed (rpm) |
Pumping Speed (m3/min) |
Bore (in) |
Water Supply (L/min) |
|||
-640mmHg (120Torr) |
-590mmHg (170Torr) |
-490mmHg (270Torr) |
-400mmHg (360Torr) |
|||||
DW-1 |
1 |
2800 |
0.24 |
0.25 |
0.27 |
0.27 |
1 |
7 |
1 |
3400 |
0.29 |
0.32 |
0.33 |
0.33 |
|||
DW-2 |
1 |
2800 |
0.38 |
0.46 |
0.5 |
0.53 |
1 |
8 |
2 |
3400 |
0.57 |
0.62 |
0.66 |
0.67 |
|||
SW-5 |
5 |
1750 |
1.51 |
1.97 |
2.22 |
2.26 |
2 |
18 |
SW-7 |
1750 |
1.88 |
2.71 |
3.1 |
3.1 |
2 |
20 |
|
SW-10 |
10 |
1750 |
2.65 |
3.25 |
3.65 |
3.7 |
2 |
25 |
SW-10D |
71/2 |
1450 |
1.95 |
2.8 |
3.2 |
3.4 |
2 |
25 |
10 |
1750 |
2.7 |
3.6 |
3.9 |
4 |
|||
SW-15 |
10 |
1450 |
4 |
4.8 |
5.2 |
5.6 |
2 |
40 |
15 |
1750 |
4.6 |
5.8 |
6.3 |
6.7 |
|||
SW-25A |
20 |
1450 |
5.4 |
6.5 |
7.8 |
8 |
2 |
45 |
25 |
1750 |
6.5 |
7.8 |
9.3 |
9.7 |
|||
SW-600 |
20 |
1450 |
8 |
8.5 |
8.9 |
9.2 |
3 |
27 |
25 |
1750 |
9 |
10 |
10.7 |
11 |
|||
SW-700 |
25 |
1450 |
9 |
10.8 |
11.9 |
12.4 |
3 |
30 |
30 |
1650 |
10 |
12.5 |
13.7 |
14.3 |
|||
40 |
1750 |
11 |
13 |
14.5 |
15 |
|||
SW-900 |
30 |
840 |
12 |
13.5 |
14 |
14 |
5 |
50 |
40 |
960 |
15 |
17 |
17 |
16.5 |
|||
50 |
1150 |
15 |
20.5 |
21 |
20 |
|||
SW-1300 |
50 |
960 |
19 |
20 |
21 |
21 |
5 |
70 |
60 |
1150 |
20 |
24 |
25 |
25 |
|||
SW-1600 |
60 |
960 |
20 |
25 |
26 |
29 |
5 |
75 |
75 |
1150 |
25 |
31 |
32 |
34 |
|||
Standard Coupling transmission type: * Coupling * Base Belt drive type: * Pulley, belt * Base * Pulley cover Option *Three-phase motor *Water-sealed special check valve *Circulating bucket *Atmosphere booster *Muffler bucket *Vacuum gauge * Pressure relief valve * Heat exchanger |